Title:
Lateral performance of pre-stressed glulam beam-to-column joints
文章编号:
1671-7627(2016)05-0028-06
作者:
李征王康郦何敏娟
同济大学 建筑工程系,上海 200092
Author(s):
LI ZhengWANG KangliHE Minjuan
Department of Structure Engineering,Tongji University,Shanghai 200092,China
关键词:
胶合木结构 梁柱节点 自复位 预应力 滞回性能
Keywords:
glulam structures beam to column joint self-centering post-tensioning hysteretic performance
分类号:
TU366.3
DOI:
10.3969/j.issn.1671-7627.2016.05.005
文献标志码:
A
摘要:
本文对一种安装预应力钢绞线的新型重型胶合木梁柱节点的抗侧力性能进行了研究,该节点通过对钢绞线施加预应力产生自复位能力,并设计一种特制“钢帽”作为耗能件,安装于梁端。为探究该试件性能,采用单调加载和低周往复加载的方式,得到试件的承载力、耗能性能、破坏模式和抗侧性能等。结果表明:节点具有良好的变形能力,加载过程中,特制“钢帽”作为主要耗能件,提供较好的耗能能力,钢绞线在加载全程均处于弹性状态。该设计达到设计目标,试件耗能及自复位性能良好。
Abstract:
The lateral performance of a pre-stressed energy dissipating beam-to-column joint for glulam heavy timber structure was investigated in this paper.Such connection incorporates post-tensioned high-strength strand to provide self-centering capacity.The energy is dissipated by a special steel cap,which is attached with the timber beam and also to prevent the end bearing failure of wood.A series of monotonic tests as well as cyclic loading tests were conducted.The tests were conducted with two different post-tension forces in the steel strands. The results prove the good moment-resisting and energy dissipation capacity of joints.The steel strand remains elastic during the entire tests and its nonlinear inelastic behavior is blamed for the deformation of wood and geometrical nonlinearity of joints.

参考文献/References:

[1] PRIESTLEY N.Seismic design philosophy for precast concrete frames[J].Structural engineering international,1996,6(1):25.
[2] KIM H J,CHRISTOPOULOS C.Numerical models and ductile ultimate deformation response of post-tensioned self-centering moment connections [J].Earthquake engineering & structural dynamics,2009,38(1):1.
[3] CHOU C C,LAI Y J.Post-tensioned self-centering moment connections with beam bottom flange energy dissipators[J].Journal of constructional steel research,2009,65(10):1931.
[4] PALERMO A,PAMPANIN S,BUCHANAN A,et al.Experimental investigations on LVL seismic resistant wall and frame subassemblies[C]//First European Conference on Earthquake Engineering and Seismology.Geneva:European Association of Earthquake Engineering(EAEE),2006.
[5] PALERMO A,PAMPANIN S,FRAGIACOMO M,et al.Innovative seismic solutions for multi-storey LVL timber buildings[C]//World Conference on Timber Engineering 2006.Portland:Oregon State University Conference Services Office,2006.
[6] BUCHANAN A,DEAM B,FRAGIACOMO M,et al.Multi-storey prestressed timber buildings in New Zealand[J].Structural engineering international,2008,18(2):166.
[7] TOBIAS S,FELICE C,ANTONIO D C,et al.Post-tensioned glulam beam-column joints with advanced damping systems:testing and numerical analysis[J].Journal of earthquake engineering,2014,18(1):147.
[8] IQBAL A,PAMPANIN S,BUCHANAN A.Seismic performance of full-scale post-tensioned timber beam-column connections [J].Journal of earthquake engineering,2016,20(3):383.
[9] PAMPANIN S,PALERMO A,BUCHANAN A,et al.Code provisions for seismic design of multi-storey post-tensioned timber buildings[C]//CIB W18 Workshop on Timber Structures.Florence:University Karlsruhe,2006.
[10] NEWCOMBE M.Seismic design of multistorey post-tensioned timber buildings[D]//IstitutoUniversitario di StudiSuperiori di Pavia,UniversitadegliStudi di Pavia:[s.n.],2008.
[11] NEWCOMBE M,CUSIEL M,PAMPANIN S,et al.Simplified design of post-tensioned-timber-frames[C]//Proceedings of the 15th World Conference on Earthquake Engineering.Lisbon,Portugal:[s.n.],2012.
[12] 中国机械工业联合会.钢结构用高强度大六角头螺栓、大六角螺母、垫圈技术条件:GB/T 1231—2006[S].北京:中国标准出版社,2006.
[13] ASTM.Standard test methods for cyclic(reversed)load test for shear resistance of vertical elements of the lateral force resisting systems for buildings[S].West Conshohocken,PA:ASTME2126,2009.

备注/Memo

备注/Memo:
收稿日期:2016-05-12
基金项目:上海市青年科技英才扬帆计划(16YF1411800); 中央高校基本科研业务费专项资金(2015KJ005)
作者简介:李征(1987—),男,内蒙古赤峰市人,助理教授,博士,主要研究方向为木结构和钢结构; 何敏娟(联系人),教授,E-mail: hemj@tongji.edu.cn.
引用本文:李征,王康郦,何敏娟.预应力胶合木梁柱节点的抗侧力性能研究[J].南京工业大学学报(自然科学版),2016,38(5):28-33..
更新日期/Last Update: 2016-09-20