|本期目录/Table of Contents|

[1]李鸿锦,程建杰,何嘉鹏.夏热冬冷地区相变石膏板相变特性的模拟[J].南京工业大学学报(自然科学版),2013,35(04):115-120.[doi:10.3969/j.issn.1671-7627.2013.04.024]
 LI Hongjin,CHENG Jianjie,HE Jiapeng.Simulation on characteristics of phase change plasterboard in hot summer and cold winter zone[J].Journal of NANJING TECH UNIVERSITY(NATURAL SCIENCE EDITION),2013,35(04):115-120.[doi:10.3969/j.issn.1671-7627.2013.04.024]
点击复制

夏热冬冷地区相变石膏板相变特性的模拟()
分享到:

《南京工业大学学报(自然科学版)》[ISSN:1671-7627/CN:32-1670/N]

卷:
35
期数:
2013年04期
页码:
115-120
栏目:
出版日期:
2013-07-01

文章信息/Info

Title:
Simulation on characteristics of phase change plasterboard in hot summer and cold winter zone
文章编号:
1671-7627(2013)04-0115-06
作者:
李鸿锦程建杰何嘉鹏
南京工业大学 城市建设与安全工程学院,江苏 南京 210009
Author(s):
LI HongjinCHENG JianjieHE Jiapeng
College of Urban Construction & Safety Engineering, Nanjing University of Technology, Nanjing 210009,China
关键词:
夏热冬冷地区 定形相变石膏板 相变温度
Keywords:
hot summer and cold winter zone figurate phase change plasterboard phase change temperature
分类号:
TU111.4+8
DOI:
10.3969/j.issn.1671-7627.2013.04.024
文献标志码:
A
摘要:
基于焓法数值模型,利用Fluent软件模拟定形相变石膏板(PCP)在不同保温位置及不同相变温度时传热的热流密度及内表面温度情况,分析适用于夏热冬冷地区PCP的参数、不同相变温度与放置位置对外墙的隔热性能的影响。结果表明:相变材料最适宜的相变温度为27 ℃,在此相变温度下,同一时刻的内、外侧位置的内表面最大温差为0.9 ℃; 相变温度为27 ℃的墙体比普通墙体约节能27.6%,此时相变材料潜热利用率为38.7%。
Abstract:
Based on enthalpy model,Fluent soft ware was used to simulate the heat flux density and inner surface temperature of figurate phase change plasterboard(PCP)in hot summer and cold winter zone under different placements and phase change temperatures. The parameters of PCP in such areas and the influence on the heat-insulating property of external wall were analyzed. The results showed that 27 ℃ was the most appropriate phase change temperature of PCP, and the maximum temperature difference between inside and outside was 0.9 ℃. The wall with PCP of phase change temperature of 27 ℃, could save 27.6% of energy than the common wall,and its latent heat utilization rate could reach 38.7%.

参考文献/References:

[1] 楚新欣,王党飞.暖通空调与既有建筑节能改造的现状与趋势[J].科技创新与应用,2012(2):189-190.
[2] 王馨,张寅平,肖伟,等.相变蓄能建筑围护结构热性能研究进展[J].科学通报,2008,53(24):3006-3013.
[3] Heim D.Isothermal storage of solar energy in building construction[J].Renewable Energy,2010,35(4):788-796.
[4] Medina M A,King J B,Zhang M.On the heat transfer rate reduction of structural insulated panels(SIPs)outfitted with phase change materials(PCMs)[J].Energy,2008,33(4):667-678.
[5] 何叶从,周杰,王厚华,等.相变墙房间传热特性研究[J].太阳能学报,2007,28(10):1085-1090.
[6] 肖伟,王馨,张群力,等.结合太阳能空气集热器的定形相变蓄热地板采暖系统实验研究[J].太阳能学报,2008,29(11):1319-1323.
[7] 中国建筑科学研究院.JGJ 134—2010夏热冬冷地区居住建筑节能设计标准[S].北京:中国建筑工业出版社,2010.
[8] 张正松,何嘉鹏,张博,等.相变石膏板应用于外墙表面夏季隔热的相变温度分析[J].建筑科学,2012,28(6):103-104.
[9] 叶宏,何汉峰,葛新石,等.利用焓法和有效热容法对定形相变材料熔解过程分析的比较研究[J].太阳能学报,2004,25(4):488-491.
[10] 邱林,吴秀芬,刘星,等.地面辐射供暖系统相变蓄能地板热工性能研究[J].燃气与热力,2007,27(2):80-81.
[11] 中国建筑科学研究院.GB 50736—2012民用建筑供暖通风与空气调节设计规范[S].北京:中国建筑工业出版社,2012.
[12] 施冠羽.低温热水有源相变墙体辐射供暖特性的研究[D].南京:南京理工大学,2009:20-21.

相似文献/References:

[1]许锦峰,黄欣鹏,吴志敏.被动式节能建筑围护结构的技术特征[J].南京工业大学学报(自然科学版),2011,33(05):60.[doi:10.3969/j.issn.1671-7627.2011.05.012]
 XU Jinfeng,HUANG Xinpeng,WU Zhimin.Technical characteristics of passive energysaving building envelope[J].Journal of NANJING TECH UNIVERSITY(NATURAL SCIENCE EDITION),2011,33(04):60.[doi:10.3969/j.issn.1671-7627.2011.05.012]

备注/Memo

备注/Memo:
收稿日期:2012-09-27
基金项目:“十二五”国家科技支撑计划(2011BAE14B06)
作者简介:李鸿锦(1989—),男,湖北武穴人,硕士,主要研究方向为相变传热与建筑节能; 程建杰(联系人),副教授,chengjianjienn@126.com..
更新日期/Last Update: 2013-07-07